JVM16-63 Miniature Circuit Breaker
Construction and Feature
The sate-of-art design
Elegant appearance; cover and handle in arc shape make comfortable operation.
Contact position indicating window
Transparent cover designed to carry label.
Handle central-staying function for circuit fault indicating
In case of overload to protect circuit, MCB handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.
High short-circuit capacity
High short-circuit capacity 10KA for whole range and 15kA capacity for current rating up to 40A because of the powerful electric arc extinguishing system.
Long electrical endurance up to 6000 cycles due to quick making mechanism.
Handle padlock device
MCB handle can be locked either at “ON” position or at “OFF” position to prevent unwanted operation of the product.
Screw terminal lock device
The lock device prevents unwanted or casual dismounting of connected terminals.
What We Do
JIEYUNG corporation has been committed to Energy meter, Breaker, waterproof distribution box integrated solutions and been provided in new energy electric connection solutions for decades.
Our products are wildly used in distributed power supply, ultra-high voltage and micro grid, and charging pile, these all need JIEYUNG CO., LTD. one-stop service and solutions. It is expected in the next 3 year to 5 year the demand will continue to rise, there will be an eruptive growth for our smart electric distribution box and we are ready for your inquiry.
What we capable are widely served integrated solutions of energy meter, breaker, waterproof distribution box for residential, commercial and industrial applications in 10+ countries and districts, as well as connection solutions on new energy, photovoltaic and lighting industry.
Categories | Superior 10kA 16 Series Circuit Breaker |
Model | JVM16-63 |
Pole No | 1, 1P+N, 2, 3, 3P+N, 4 |
Rated voltage | AC 230/400V |
Rated current (A) | 1,2,3,4,6, 10, 13, 16, 20, 25, 32, 40, 50, 63 |
Tripping curve | B,C,D |
Energy limiting class | 3 |
Rated frequency | 50/60Hz |
Rated impulse withstand voltage | 6.2kV |
High short-circuit breaking capacity (lnc) | 10KA |
Rated series short-circuit breaking capacity(cs) | 7.5KA |
Eletr-mechanical endurance | 20000 |
Terminal protection | IP20 |
Standard | IEC61008 |
Pole No. | 1, 1P+N, 2, 3, 3P+N, 4 |
Rated voltage | AC 230/400V |
Rated current (A) | 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 |
Tripping curve | B, C, D |
High short-circuit breaking capacity (Icn) | 10kA |
Rated service short-circuit breaking capacity(Ics) | 7.5kA |
Rated frequency | 50/60Hz |
Energy limiting class | 3 |
Rated impulse withstand voltage | 6.2kV |
Electro-mechanical endurance | 20000 |
Contact position indication | |
Connection terminal | Pillar terminal with clamp |
Connection capacity | Rigid conductor up to 25mm2 |
Terminal connection Height | 19mm |
Fastening torque | 2.0Nm |
Installation | On symmetrical DIN rail 35.5mm |
Panel mounting |